<LOGO>
FM Transmitter Measurement Report
Created: 2025-01-13 20-29-35
Measuring equipment: P75/P175/P275
http://pira.cz
Station Details
Frequency Signal Reception Station Name
96.90 MHz 4/5, 57 dBuV VOLTAGE
Pilot RDS Phase Difference
7.1 kHz 3.4 kHz 24 deg
Frequency Deviation
Limit Measuring Tolerance
75,0 kHz 0,0 kHz
MIN Hold Max. Samples at Total Samples % above 75,0 kHz
21 kHz 75 kHz 9849 40,4711
Modulation Power
Limit Measuring Tolerance
10,0 dBr 0,0 dBr
MIN AVE MAX % above 10,0 dBr
7,1 dBr 7,80 dBr 8,5 dBr 0,0
Radio Data System
PS PI PTY TP TA  MS   DI   CT 
"VOLTAGE " FE45 10 (Pop M) 1 0 0 5 20:29, 13.01.2025
RT
"VOLTAGE - Dance music "
AF EON
96.9, 102.9 MHz -
FM Scope Station: 96.90 MHz, signal: 4/5 (56 dBuV) Max at: 75 kHz MIN: 21 kHz % above 75 kHz: 40,4711 Acquired: 2025/01/13 20:28:31 Total samples: 9849 Equivalent time: 0:08:12 0 10 20 30 40 50 60 70 80 90 100 110 120 Frequency Deviation [kHz] 0 1000 2000
FM Scope MAX: 8,5 dBr MIN: 7,1 dBr AVE: 7,80 dBr % above 10,0 dBr: 0,0 Last value: 8,0 dBr (2025/01/13 20:28:30) Station: 96.90 MHz, signal: 4/5 (55 dBuV) 20:22 20:23 20:24 20:25 20:26 20:27 20:28 0 50 100 Dev. MAX [kHz] 0 5 Pm [dBr] 0 5 Signal Quality